Independent recall search Not a government website Verify instructions at the issuing-agency source
CPSC source record The boilers can release carbon monoxide (CO) due t Ongoing

Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported

Recall Date: 2025-02-27 Recalling Firm: Burnsen SA, of Belgium Record Ref: 10179

FINDARECALL QUICK READ

What this record tells you

This CPSC record concerns Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported and names Burnsen SA, of Belgium as the recalling firm. Use the source fields below to narrow the match, then verify the exact item and current remedy on the issuing-agency page.

  • Firm: Burnsen SA, of Belgium
  • Classification: The boilers can release carbon monoxide (CO) due t
  • Status: Ongoing
  • Recall date: 2025-02-27
Best identifiers to check for a CPSC record

Compare model, item/style number, serial range, manufacturing date, importer, retailer, color, and other physical identifiers listed in the notice.

A CPSC photograph may show only one variation, so use the model/serial information and remedy instructions as the stronger match.

Product Description & Identification

The recalled Prestige Solo, Prestige Excellence, and Aerco Esteem boilers are wall-hung condensing gas boilers housed in a white metal box. "Prestige" is printed on the white front panel of the recalled Prestige Solo and Prestige Excellence boilers. "Aerco" is printed on the front of the recalled Esteem boilers. Please visit the Triangle Tube recall website for directions on identifying if you have a recalled boiler by serial number, which can be located either on the Boiler Rating Label located on the white front panel, on a panel on the right hand side of the boiler, or behind the boiler front door. The following models and serial number ranges are included in this recall. Product Name Item Code Product Description Serial Number Range Start Serial Number Range End Date of Manufacture Prestige Solo - PA PA110 Prestige Solo PA Series PA044936 PA147874 PA155 Prestige Solo PA Series PA045337 PA147522 PA175 Prestige Solo PA Series PA044728 PA148532 PA250 Prestige Solo PA Series PA044768 PA149487 PA299 Prestige Solo PA Series PA045398 PA146746 PA399 Prestige Solo PA Series PA045420 PA148752 PA80 Prestige Solo PA Series PA044058 PA139939 Dec 2015 - Apr 2019 Prestige Solo PT PT110 Prestige Solo PT Series PT0000110 PT0053558 PT110 Prestige Solo PT Series PTA002845 PTA037637 PT110LP Prestige Solo PT Series PT0000928 PT0053557 PT110LP Prestige Solo PT Series PTA002645 PTA002764 PT175 Prestige Solo PT Series PT0002849 PT0053776 PT175 Prestige Solo PT Series PTA003087 PTA037557 PT250 Prestige Solo PT Series PT0002588 PT0053319 PT250 Prestige Solo PT Series PTA003207 PTA037467 PT399 Prestige Solo PT Series PT0005962 PT0052417 PT399 Prestige Solo PT Series PTA003388 PTA037377 PT399HP Prestige Solo PT Series PT0010893 PT0052394 PT399HP Prestige Solo PT Series PTA003496 PTA097961 PT60 Prestige Solo PT Series PT0002188 PT0051954 PT60 Prestige Solo PT Series PTA002810 PTA008253 Dec 2011 - Dec 2015 Prestige Excellence - PTE PTE110LP Prestige Excellence PT PT0001588 PT0053690 PTE110LP Prestige Excellence PTE PTE030446 PTE030479 PTE110 Prestige Excellence PT000568 PT0053624 PTE110 Prestige Excellence PTEA PTA002889 PTA003086 PTE110 Prestige Excellence PTE PTE049177 PTE049177 Dec 2011 - Dec 2015 Prestige Excellence - PEA PEA110 Prestige Excellence PEA PEA078169 PEA143958 Dec 2015 - Apr 2019 Aerco Esteem PT399ES Aerco Esteem AE1100 AE1236 PT399HP Aerco Esteem AE1237 AE1239 DF48650G/BK/P DF48650G/BK/P/LP DF48650G/S/P Dec 2011 - Dec 2015

Reason for Recall / Hazard Identified

Hazard: The boilers can release carbon monoxide (CO) due to delayed ignitions or component damage, posing a risk of serious injury or death.. The recalled Prestige Solo, Prestige Excellence, and Aerco Esteem boilers are wall-hung condensing gas boilers housed in a white metal box. "Prestige" is printed on the white front panel of the recalled Prestige Solo and Prestige Excellence boilers. "Aerco" is printed on the front of the recalled Esteem boilers. Please visit the Triangle Tube recall website for directions on identifying if you have a recalled boiler by serial number, which can be located either on the Boiler Rating Label located on the white front panel, on a panel on the right hand side of the boiler, or behind the boiler front door. The following models and serial number ranges are included in this recall. Product Name Item Code Product Description Serial Number Range Start Serial Number Range End Date of Manufacture Prestige Solo - PA PA110 Prestige Solo PA Series PA044936 PA147874 PA155 Prestige Solo PA Series PA045337 PA147522 PA175 Prestige Solo PA Series PA044728 PA148532 PA250 Prestige Solo PA Series PA044768 PA149487 PA299 Prestige Solo PA Series PA045398 PA146746 PA399 Prestige Solo PA Series PA045420 PA148752 PA80 Prestige Solo PA Series PA044058 PA139939 Dec 2015 - Apr 2019 Prestige Solo PT PT110 Prestige Solo PT Series PT0000110 PT0053558 PT110 Prestige Solo PT Series PTA002845 PTA037637 PT110LP Prestige Solo PT Series PT0000928 PT0053557 PT110LP Prestige Solo PT Series PTA002645 PTA002764 PT175 Prestige Solo PT Series PT0002849 PT0053776 PT175 Prestige Solo PT Series PTA003087 PTA037557 PT250 Prestige Solo PT Series PT0002588 PT0053319 PT250 Prestige Solo PT Series PTA003207 PTA037467 PT399 Prestige Solo PT Series PT0005962 PT0052417 PT399 Prestige Solo PT Series PTA003388 PTA037377 PT399HP Prestige Solo PT Series PT0010893 PT0052394 PT399HP Prestige Solo PT Series PTA003496 PTA097961 PT60 Prestige Solo PT Series PT0002188 PT0051954 PT60 Prestige Solo PT Series PTA002810 PTA008253 Dec 2011 - Dec 2015 Prestige Excellence - PTE PTE110LP Prestige Excellence PT PT0001588 PT0053690 PTE110LP Prestige Excellence PTE PTE030446 PTE030479 PTE110 Prestige Excellence PT000568 PT0053624 PTE110 Prestige Excellence PTEA PTA002889 PTA003086 PTE110 Prestige Excellence PTE PTE049177 PTE049177 Dec 2011 - Dec 2015 Prestige Excellence - PEA PEA110 Prestige Excellence PEA PEA078169 PEA143958 Dec 2015 - Apr 2019 Aerco Esteem PT399ES Aerco Esteem AE1100 AE1236 PT399HP Aerco Esteem AE1237 AE1239 DF48650G/BK/P DF48650G/BK/P/LP DF48650G/S/P Dec 2011 - Dec 2015

How to Check Whether Your Product Matches

A matching product name or photograph is not enough by itself. Compare every identifier available on your item or packaging with the official notice.

  1. Confirm the full product and brand or recalling-firm name.
  2. Compare package size, color, flavor, model, style, or configuration when listed.
  3. Check UPC, lot, batch, serial, date code, recall number, or USDA establishment number.
  4. Review the recall date and distribution information without assuming every seller is listed.
  5. Open the official CPSC source below and follow its current instructions.

If a required identifier is missing, contact the recalling company or issuing agency through the official notice rather than guessing.

Consumer Action Recorded in the Source

Consumers with recalled boilers should immediately contact Triangle Tube to schedule a free boiler inspection and, if applicable, free installation of a new boiler ignition system. Consumers who continue using the recalled boilers while awaiting repair should have working carbon monoxide alarms on each level of their homes and outside sleeping areas. Consumers who do not have a carbon monoxide alarm can contact Triangle Tube to have one shipped to them free of charge.. Triangle Tube toll-free at 877-574-5036 from 8 a.m. to 5 p.m. ET Monday through Friday, by email at productrecall@triangletube.com, or online at https://triangletube.com/products/product-recall/ or at www.triangletube.com and click on "PRODUCT RECALL" for more information.

Distribution & Affected States

Nationwide retail and online distribution

Source-Provided Product Images

Product image supplied with the source record for Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported
Product image supplied with the source record for Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported
Product image supplied with the source record for Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported
Product image supplied with the source record for Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported
Product image supplied with the source record for Triangle Tube Recalls Prestige and Aerco Esteem Gas Boilers Due to Carbon Monoxide (CO) Poisoning Hazard; Two Deaths Reported

Image limitation: An image may show only one package, color, size, or model. Do not use a photograph alone to decide whether your product is affected.

Verify With the Issuing Agency

This record was last updated in our index on 2026-07-27 11:37:08 UTC. Because recall enforcement statuses and instructions evolve, always verify details directly with the issuing government agency.

Open CPSC Source Record →

Record Transparency

Issuing agency
CPSC
Source ID
10179
Indexed update
2026-07-27 11:37:08 UTC
Official source
Open issuing-agency record