Independent recall search Not a government website Verify instructions at the issuing-agency source
CPSC source record The blocked vent switch (BVS) can fail to shut dow Ongoing

U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard

Recall Date: 2024-03-14 Recalling Firm: U.S. Boiler Company LLC, of Lancaster, Pennsylvania Record Ref: 9894

FINDARECALL QUICK READ

What this record tells you

This CPSC record concerns U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard and names U.S. Boiler Company LLC, of Lancaster, Pennsylvania as the recalling firm. Use the source fields below to narrow the match, then verify the exact item and current remedy on the issuing-agency page.

  • Firm: U.S. Boiler Company LLC, of Lancaster, Pennsylvania
  • Classification: The blocked vent switch (BVS) can fail to shut dow
  • Status: Ongoing
  • Recall date: 2024-03-14
Best identifiers to check for a CPSC record

Compare model, item/style number, serial range, manufacturing date, importer, retailer, color, and other physical identifiers listed in the notice.

A CPSC photograph may show only one variation, so use the model/serial information and remedy instructions as the stronger match.

Product Description & Identification

This recall involves gas-fired residential boilers with brand names U.S. Boiler, New Yorker Boiler, Advantage, FORCE and Archer. The following boiler models that are currently installed at altitudes greater than 5,400 ft. above sea level are part of this recall. The U.S. boiler ES2 and Series 3 models are blue with a black top front and black vents on the front. The logo is located on the black top front of the boiler. The X-2 model has a solid teal color. The logo is located in the front middle of the boiler. The Lancer model is gray with a blue top. The logo is located in the front middle of the boiler. The Force G-3 model is solid gray. The logo is located in the front middle of the boiler. The CGE and CGF models are solid green The logo is located in the front middle of the boiler. The model and serial numbers are located on the boiler rating plate, which is on the top panel of the ES2 and Series 3 models, and on the inside vestibule (behind removable door) on the right side panel for X-2, CG-F, CG-E, AG , Force and Archer models. All of the models are about 40 inches tall from the floor to the top of the jacket. U.S. Boiler ES2 models ES23, ES24, ES25, ES26, ES27, ES28, ES29 (with or without "-N" or "-P" suffix) U.S. Boiler Series 3 models 303, 304, 305, 306, 307, 308, 309 (with or without "-N" or "-P" suffix) U.S. Boiler X-2 models X-202, X-203, X-204, X-205, X-206, X-207, X-208, X-209 New Yorker CG-E models CG30E, CG40E, CG50E, CG60E, CG70E, CG80E, CG90E New Yorker CG-F models CG20F, CG30F, CG40F, CG50F, CG60F, CG70F, CG80F, CG90F Advantage AG models AG3, AG4, AG5, AG6 FORCE models FORCE02E, FORCE03E, FORCE04E, FORCE05E, FORCE06E, FORCE07E, FORCE08E, FORCE09E Archer Boilers Lancer models LCR-2-038, LCR-3-068, LCR-4-102, LCR-5-136, LCR-6-170

Reason for Recall / Hazard Identified

Hazard: The blocked vent switch (BVS) can fail to shut down the burners if the boilers are installed at altitudes above 5,400 feet and the vent system becomes blocked. In such an event, the boiler can emit excessive amounts of carbon monoxide into the home, posing a carbon monoxide (CO) poisoning hazard to consumers.. This recall involves gas-fired residential boilers with brand names U.S. Boiler, New Yorker Boiler, Advantage, FORCE and Archer. The following boiler models that are currently installed at altitudes greater than 5,400 ft. above sea level are part of this recall. The U.S. boiler ES2 and Series 3 models are blue with a black top front and black vents on the front. The logo is located on the black top front of the boiler. The X-2 model has a solid teal color. The logo is located in the front middle of the boiler. The Lancer model is gray with a blue top. The logo is located in the front middle of the boiler. The Force G-3 model is solid gray. The logo is located in the front middle of the boiler. The CGE and CGF models are solid green The logo is located in the front middle of the boiler. The model and serial numbers are located on the boiler rating plate, which is on the top panel of the ES2 and Series 3 models, and on the inside vestibule (behind removable door) on the right side panel for X-2, CG-F, CG-E, AG , Force and Archer models. All of the models are about 40 inches tall from the floor to the top of the jacket. U.S. Boiler ES2 models ES23, ES24, ES25, ES26, ES27, ES28, ES29 (with or without "-N" or "-P" suffix) U.S. Boiler Series 3 models 303, 304, 305, 306, 307, 308, 309 (with or without "-N" or "-P" suffix) U.S. Boiler X-2 models X-202, X-203, X-204, X-205, X-206, X-207, X-208, X-209 New Yorker CG-E models CG30E, CG40E, CG50E, CG60E, CG70E, CG80E, CG90E New Yorker CG-F models CG20F, CG30F, CG40F, CG50F, CG60F, CG70F, CG80F, CG90F Advantage AG models AG3, AG4, AG5, AG6 FORCE models FORCE02E, FORCE03E, FORCE04E, FORCE05E, FORCE06E, FORCE07E, FORCE08E, FORCE09E Archer Boilers Lancer models LCR-2-038, LCR-3-068, LCR-4-102, LCR-5-136, LCR-6-170

How to Check Whether Your Product Matches

A matching product name or photograph is not enough by itself. Compare every identifier available on your item or packaging with the official notice.

  1. Confirm the full product and brand or recalling-firm name.
  2. Compare package size, color, flavor, model, style, or configuration when listed.
  3. Check UPC, lot, batch, serial, date code, recall number, or USDA establishment number.
  4. Review the recall date and distribution information without assuming every seller is listed.
  5. Open the official CPSC source below and follow its current instructions.

If a required identifier is missing, contact the recalling company or issuing agency through the official notice rather than guessing.

Consumer Action Recorded in the Source

Consumers with the recalled boilers should immediately contact U.S. Boiler to receive a free repair that includes a free replacement main burner gas orifice and a free replacement blocked vent switch if needed. Consumers who continue use of the boilers while awaiting repair should have working carbon monoxide alarms outside of sleeping areas and on each floor of the home.. U.S. Boiler toll-free at 888-432-8887 from 8 a.m. to 5 p.m. ET Monday through Friday, email at info@usboiler.net, or online at https://s3-us-west-2.amazonaws.com/catsy.782/high+altitude+homeowner+recall+letter3.pdf or usboiler.net, archerboiler.com, or newyorkerboiler.com and click on "Safety Recall Information: High Altitude Gas Boilers" on the home page for more information.

Distribution & Affected States

Nationwide retail and online distribution

Source-Provided Product Images

Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard
Product image supplied with the source record for U.S. Boiler Company Recalls Gas-Fired Hot Water Residential Boilers Due to Carbon Monoxide Poisoning Hazard

Image limitation: An image may show only one package, color, size, or model. Do not use a photograph alone to decide whether your product is affected.

Verify With the Issuing Agency

This record was last updated in our index on 2026-07-27 11:37:08 UTC. Because recall enforcement statuses and instructions evolve, always verify details directly with the issuing government agency.

Open CPSC Source Record →

Record Transparency

Issuing agency
CPSC
Source ID
9894
Indexed update
2026-07-27 11:37:08 UTC
Official source
Open issuing-agency record