Independent recall search Not a government website Verify instructions at the issuing-agency source
CPSC source record The load center can overheat, posing thermal burn Ongoing

Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards

Recall Date: 2022-06-16 Recalling Firm: Schneider Electric USA Inc., of Lexington, Kentucky Record Ref: 9325

FINDARECALL QUICK READ

What this record tells you

This CPSC record concerns Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards and names Schneider Electric USA Inc., of Lexington, Kentucky as the recalling firm. Use the source fields below to narrow the match, then verify the exact item and current remedy on the issuing-agency page.

  • Firm: Schneider Electric USA Inc., of Lexington, Kentucky
  • Classification: The load center can overheat, posing thermal burn
  • Status: Ongoing
  • Recall date: 2022-06-16
Best identifiers to check for a CPSC record

Compare model, item/style number, serial range, manufacturing date, importer, retailer, color, and other physical identifiers listed in the notice.

A CPSC photograph may show only one variation, so use the model/serial information and remedy instructions as the stronger match.

Product Description & Identification

This recall involves indoor, outdoor and original equipment manufacturer (OEM) Square D QO Plug-On Neutral Load Centers that were installed in homes, recreational vehicles, or commercial establishments, including restaurants, manufacturing facilities and warehouses, commercial lighting and others. The circuit breaker boxes were sold in gray and come in various sizes (square and rectangular). The recalled circuit breaker boxes were manufactured between February 2020 and January 2022, with date codes between 200561 and 220233. For installed outdoor load centers, the manufacturing date codes are printed on the inside of the cover or door of the unit or on the box itself when the cover or door is open. For installed indoor load centers, a qualified electrician can locate the interior date codes that are not visible to the home owner. Circuit breaker boxes with covers that were manufactured between December 2019 and March 2022 are also included in this recall. The affected catalog/part numbers can be found inside the electrical panel doors for both the U.S. and Canada. Recalled Electrical Panel U.S. and Canada Catalog /Part Numbers CQO116L100PGRB QO130M200PRB QOC30UFWG CQO116M100PRB QO140L200PGRB QOC30UFWGW CQO116M60PRB QO140M200PRB QOC30US CQO124L125PGRB QO142L225PGRB QOC32UF CQO124M100PRB QO142M200PRB QOC32UFW CQO140L200PGRB QO142M225PRB QOC40UF CQO140M200PRB QO1816M200PFTRB QOC40UFW NQC20FWG QO816L100PRB QOC40US NQC20FWGW QOC12UF QOC42UF NQC30FWG QOC12US QOC42UFW NQC30FWGW QOC16UF QOC42US QO112L125PGRB QOC16UFW QOC54UF QO112L200PGRB QOC16US QOC54UFW QO112M100PRB QOC20U100F QOC60UF QO116L125PGRB QOC20U100FW QOCMF30UC QO116M100PRB QOC20U100S QOCMF30UCW QO120M100PRB QOC20UFWG QOCMF42UC QO120M150PRB QOC20UFWGW QOCMF42UCW QO120M200PRB QOC24UF QOCMF54UC QO124L125PGRB QOC24UFW QOCMF54UCW QO124M100PRB QOC24US QOCMF60UC QO124M125PRB QOC30U125C QOCMF60UCW QO130L200PGRB QOC30UF QO130M150PRB QOC30UFW

Reason for Recall / Hazard Identified

Hazard: The load center can overheat, posing thermal burn and fire hazards.. This recall involves indoor, outdoor and original equipment manufacturer (OEM) Square D QO Plug-On Neutral Load Centers that were installed in homes, recreational vehicles, or commercial establishments, including restaurants, manufacturing facilities and warehouses, commercial lighting and others. The circuit breaker boxes were sold in gray and come in various sizes (square and rectangular). The recalled circuit breaker boxes were manufactured between February 2020 and January 2022, with date codes between 200561 and 220233. For installed outdoor load centers, the manufacturing date codes are printed on the inside of the cover or door of the unit or on the box itself when the cover or door is open. For installed indoor load centers, a qualified electrician can locate the interior date codes that are not visible to the home owner. Circuit breaker boxes with covers that were manufactured between December 2019 and March 2022 are also included in this recall. The affected catalog/part numbers can be found inside the electrical panel doors for both the U.S. and Canada. Recalled Electrical Panel U.S. and Canada Catalog /Part Numbers CQO116L100PGRB QO130M200PRB QOC30UFWG CQO116M100PRB QO140L200PGRB QOC30UFWGW CQO116M60PRB QO140M200PRB QOC30US CQO124L125PGRB QO142L225PGRB QOC32UF CQO124M100PRB QO142M200PRB QOC32UFW CQO140L200PGRB QO142M225PRB QOC40UF CQO140M200PRB QO1816M200PFTRB QOC40UFW NQC20FWG QO816L100PRB QOC40US NQC20FWGW QOC12UF QOC42UF NQC30FWG QOC12US QOC42UFW NQC30FWGW QOC16UF QOC42US QO112L125PGRB QOC16UFW QOC54UF QO112L200PGRB QOC16US QOC54UFW QO112M100PRB QOC20U100F QOC60UF QO116L125PGRB QOC20U100FW QOCMF30UC QO116M100PRB QOC20U100S QOCMF30UCW QO120M100PRB QOC20UFWG QOCMF42UC QO120M150PRB QOC20UFWGW QOCMF42UCW QO120M200PRB QOC24UF QOCMF54UC QO124L125PGRB QOC24UFW QOCMF54UCW QO124M100PRB QOC24US QOCMF60UC QO124M125PRB QOC30U125C QOCMF60UCW QO130L200PGRB QOC30UF QO130M150PRB QOC30UFW

How to Check Whether Your Product Matches

A matching product name or photograph is not enough by itself. Compare every identifier available on your item or packaging with the official notice.

  1. Confirm the full product and brand or recalling-firm name.
  2. Compare package size, color, flavor, model, style, or configuration when listed.
  3. Check UPC, lot, batch, serial, date code, recall number, or USDA establishment number.
  4. Review the recall date and distribution information without assuming every seller is listed.
  5. Open the official CPSC source below and follow its current instructions.

If a required identifier is missing, contact the recalling company or issuing agency through the official notice rather than guessing.

Consumer Action Recorded in the Source

Schneider Electric is directly contacting all known retailers, distributors, homeowners, and any other individuals that purchased or installed the recalled product. All purchasers and installers should immediately contact Schneider Electric to arrange to have the recalled load centers inspected by trained electricians to determine if replacement or repair is required. This inspection and any resulting replacement or repair is free of charge. Consumers can find the catalog number and date code on indoor load centers inside the door of the panel. Consumers should immediately contact Schneider Electric to arrange to have the recalled load center inspected by a trained electrician to determine if repair is required. This inspection and any resulting repair is free of charge. Consumers who continue to use the load centers while awaiting the free repair should have working smoke alarms in their homes. For uninstalled products, consumers should contact Schneider Electric for a free repair or replacement.. Schneider Electric Technical toll-free at 888-778-2733 from 8 a.m. through 8 p.m. ET Monday through Friday, online at www.se.com/us/qoloadcenter-safetyrecallnotice or at www.se.com/us/en/ and click on Recall Safety Notice for more information.

Distribution & Affected States

Nationwide retail and online distribution

Source-Provided Product Images

Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards
Product image supplied with the source record for Schneider Electric™ Recalls 1.4 Million Electrical Panels Due to Thermal Burn and Fire Hazards

Image limitation: An image may show only one package, color, size, or model. Do not use a photograph alone to decide whether your product is affected.

Verify With the Issuing Agency

This record was last updated in our index on 2026-07-27 11:37:09 UTC. Because recall enforcement statuses and instructions evolve, always verify details directly with the issuing government agency.

Open CPSC Source Record →

Record Transparency

Issuing agency
CPSC
Source ID
9325
Indexed update
2026-07-27 11:37:09 UTC
Official source
Open issuing-agency record